SITRANS FX300
Description
The SITRANS FX300 vortex flowmeter provides accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure compensation.
The vortex flowmeter product program consists of two types of flowmeters, a flange and a sandwich version, making Siemens unique as it covers all possible applications. The flange version is available with a single or dual converter, whereas the sandwich version is only available with a single converter. Both versions have the temperature sensor integrated and the pressure sensor as an option.
The SITRANS FX300 vortex flowmeter is available in a compact or remote version (Cable length: 5m, 10m or 15m).
This product is also available as a customized product, please see .
Key applications for the SITRANS FX300 are found in supply processes (auxiliary service), Chemical industry, HVAC, Power plants, Food & beverage industry and Oil & gas industry.
Detail
Measuring range |
Use calculation and sizing program (link) |
Nominal size flanged version Nominal size Sandwich version |
From DN15 to DN300 (½” to 12”) From DN15 to DN100 (½” to 4”) |
Accuracy |
Steam and gases: +/- 1% Liquids: +/- 0.75% |
Input / output |
4 – 20 mA, Pulse/Freq. 0.5 Hz, 24V DC as NAMUR |
Communication |
HART |
Power supply |
24V DC as NAMUR |
Operational pressure |
Max 100 Bar (higher pressure on request) |
Ambient temperature |
From -40 to 85°C (-40 to 185 °F) |
Medium temperature |
From -40 °C to 240 °C (-40 to 464 °F) |
Display |
2 lines, 10 characters per line Languages: German, English and French |
Transmitter Enclosure |
IP 66 / 67 Aluminum Seawater Resistant |
Sensor Material |
1.4404/316L, Hastelloy C22 (on request) |
Approval |
ATEX ll 2G EEx d ia [ia] llC T6 FM Class I, II, III Div. 1 & 2 |
Benefits
- Maintenance-free due to fully welded sensor construction providing excellent stability and reliability
- Contains three measuring points in one device with no extra equipment, installation or cabling costs
- Saves downtime because of isolation valve, which makes an exchange of pressure sensor possible without interrupting the process
- Easy installation because of Plug & Play
- Redundant system as a dual transmitter version is available