Print

Rotary Piston

rotary pistonRotary piston flow meter SITRANS F R

Description

SITRANS F R rotary piston flow meters from Siemens are bestsellers. The benefits offered by their conventional mechanical measuring technique include reliability, precision and a robust design for measuring aggressive media and high-viscosity fluids. Viscosities ranging from less than one mPa.s to 350,000 mPa.s are no problem for the reliable rotary-piston meter

Rotary piston flow meter application examples: Petroleum industry, Raw material industry

Detail

Media Temperature Max. 300 °C
Max. 572 °F
Accuracy ±0,2%
Liquid Pressure Up to 63 bar 
Up to 914 psi

Benefits

  • High measuring accuracy (approved for custody transfer)
  • Suitable for flow rates up to 1000 l/min (264 USgpm)
  • Low dependence on viscosity
  • Low pressure drop
  • Simple compact design
  • Wide range of available materials, e.g. plastic lining for particularly corrosive liquids

Print

Differential Pressure

differential pressureDifferential pressure flow meter: SITRANS F O

Description

Differentiall pressure measurement is a universal flow measurement for liquids, gases and vapors. Differential pressure flow meter always provide accurate results even with large bores, high temperature and extreme pressure.
Primary differential pressure devices, like SITRANS F O orifice, are standardized mechanical flow sensors according DIN EN ISO 5167 which are used for volume and mass flow measurement. The SITRANS F O orifice are suitable for non-corrosive and corrosive gases, vapors and liquids; permissible operating temperature -60 to +570 °C. The created differential pressue will be converted with the help of a differential pressure transmitter SITRANS P delta P into a proportional flow signal. For calculation of the SITRANS F O orifice to DIN EN ISO 5167 is an completed filled out questionnaire necessary.

Differntial pressure flow meter application examples: Power stations, Petrochemical industry, Chemical industry

Detail

Primaries / Differential pressure devices

 

-Mounting between flanges with welded connections

Orifice with annular chamber or single tappings 
Metering pipe with orifice plate, annular chamber or single tappings

Further: 
Flanged orifice plate with flange tappings 
ISA-1932-Nozzle 
Venturi nozzle 
Classical venturi

Orifice

Nominal Sizes From DN 10 to DN 1000 
From ½ inch to 40 inches
Temperature Range From -60 to 570 °C 
From -76 to 1058 °F
Operating Pressure Max. 315 bar 
Max. 4570 psi
Process Connections Thread G½ and ½-14 NPT 
cutting ring 
Welding
Orifice Material 1.7335, 1.4404. 1.4571, 1.4576 and further materials on request

Benefits

  • Orifice flowmeters are very robust and can be used in a wide range of nominal diameters
  • Suitable for wide ranges of temperature and pressure
  • No calibration required as the process is standardized
  • The electronics required in addition can be used over a long distance from the measuring location
  • The differential pressure measurement is well known and has a large installed base

Print

Variable Area

variable areaVariable area flowmeters SITRANS F VA 250

Description

The SITRANS F VA 250 variable area flowmeters (rotameter) with a standard length of 250 mm (9.84 inch) and their completely metal design can be used to measure many different types of liquids and gases passing through closed piping. The robust design of the rotameter means that they can also be used in harsh conditions. Different types of flanges, liners and float materials satisfy the requirements of the pharmaceutical and chemical industries.

Variable area flowmeters application examples: Chemical industry, Water, Power generation and distribution

 

Detail

Ambient Temperature From -40 to 80 °C 
From -40 to 176 °F
Accuracy ± 1.6% for liquids 
± 2.0% for gases
Flanges EN 1092-1 
ANSI
Fitting Stainless steel 1.4404/1.4571
Float Stainless steel 1.4404/1.4571 
Hastelloy 
PTFE
Enclosure Ratings IP 65 
IP 66
Approvals ATEX

Benefits

  • Standard design available at short notice
  • Robust all-metal fitting with impact-resistant housing cover
  • Can also be used for corrosive and flammable media
  • Use possible at high pressures and temperatures
  • Product and percentage scales
  • Can be optionally fitted with heating and cooling sheaths
  • Contamination-insensitive guiding of float

 

Print

Product Variation Request - PVR

This page explains how to order a non-standard product

Definition of PVR

Siemens offers you the possibility to customize your product. We call these applications for Product Variation Requests (PVR).

A PVR is an application for a product which is not defined within the order structure and is therefore not a selectable option within the PIA Life Cycle Portal either.

If you should be interested in a custom-designed device, then please consult your responsible sales person or send us a support request

Print

Vortex

SITRANS FX300SITRANS FX300

Description

The SITRANS FX300 vortex flowmeter provides accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure compensation.
The vortex flowmeter product program consists of two types of flowmeters, a flange and a sandwich version, making Siemens unique as it covers all possible applications. The flange version is available with a single or dual converter, whereas the sandwich version is only available with a single converter. Both versions have the temperature sensor integrated and the pressure sensor as an option.
The SITRANS FX300 vortex flowmeter is available in a compact or remote version (Cable length: 5m, 10m or 15m).
This product is also available as a customized product, please see Product Variation Request (PVR).

Key applications for the SITRANS FX300 are found in supply processes (auxiliary service), Chemical industry, HVAC, Power plants, Food & beverage industry and Oil & gas industry.

 

Detail

Measuring range Use calculation and sizing program (link)
Nominal size flanged version 
Nominal size Sandwich version
From DN15 to DN300 (½” to 12”) 
From DN15 to DN100 (½” to 4”)
Accuracy Steam and gases: +/- 1%
Liquids: +/- 0.75%
Input / output 4 – 20 mA, Pulse/Freq. 0.5 Hz, 24V DC as NAMUR
Communication HART
Power supply 24V DC as NAMUR
Operational pressure Max 100 Bar (higher pressure on request)
Ambient temperature From -40 to 85°C (-40 to 185 °F)
Medium temperature From -40 °C to 240 °C (-40 to 464 °F)
Display 2 lines, 10 characters per line 
Languages: German, English and French
Transmitter Enclosure IP 66 / 67 Aluminum Seawater Resistant
Sensor Material 1.4404/316L, Hastelloy C22 (on request)
Approval ATEX ll 2G EEx d ia [ia] llC T6 
FM Class I, II, III Div. 1 & 2

Benefits

  • Maintenance-free due to fully welded sensor construction providing excellent stability and reliability
  • Contains three measuring points in one device with no extra equipment, installation or cabling costs
  • Saves downtime because of isolation valve, which makes an exchange of pressure sensor possible without interrupting the process
  • Easy installation because of Plug & Play
  • Redundant system as a dual transmitter version is available